BJX51-20/4防爆接线端子箱非标定制外形及安装举例
壳体型号型号ABCDE进线口数量及规格出线口数量及规格备注 
Ⅰ型BJX-20/42001851001401001-G3/4"4-G1/2"ExdⅡBT6 
Ⅱ型BJX-20/82422151361641121-G1"7-G3/4" 
Ⅲ型BJX-20/163242802142351321-G1/2"7-G3/4" 
Ⅳ型BJX-20/244222863162351321-G1/2"11-G3/4" 
Ⅴ型BJX-20/364223593203151341-G1/2"13-G3/4"
壳体型号型号ABCDEF进线口数量及规格出线口数量及规格备注 
Ⅰ型BJX-20/8270290160160113991-G3/4"6-G1/2"ExdⅡCT6 
Ⅱ型BJX-20/163303602202201191041-G11/2"6-G3/4" 
Ⅲ型BJX-20/243704082602601351191-G1/2"10-G3/4" 
Ⅳ型BJX-20/36(48)4604983503501401241-G1/2"12-G3/4"
壳体型号型号ABCDEFGH进线口数量及规格出线口数量及规格备注 
Ⅰ型BJX-20/201902262749212423812981-G1"3-G3/4"ExeⅡT6 
Ⅱ型BJX-20/20190226318.515019033212981-G11/2"3-G1" 
Ⅲ型BJX-20/30250210378.519022633212981-G1/2"4-G1" 
Ⅳ型BJX-20/6025035140021025040413981-G2"6-G1" 
Ⅴ型BJX-20/80300351428.516020035413982-G2"7-G1" 
Ⅵ型BJX-20/12030035142926030045413982-G2"9-G1"
 BJX51-20/4防爆接线端子箱非标定制外技术特点
1.防爆接线箱在380V以下电路中,作为各种电器设备接线,分线用.
2.材质有玻璃纤维不饱和树脂,不锈钢,铸铝合金外壳,表面喷涂,外形美观.
3.防爆接线箱采用曲路密封结构,防水防尘效果好.
4.采用模块式结构,端子数,进出线口方向,数量不限,可满足用户各种要求.
5.钢管或电缆布线.
.防爆接线箱符合GB3836-2000,IEC60079,GB12476.1-2000,IEC61241标准要求
防爆接线箱是各种高危场所使用的特殊设备,和民用接线箱比
防止过电的时候产生电火花而引发爆炸接线。在爆炸危险区分线,接线用,能实现防爆炸,安全
 BJX51-20/4防爆接线端子箱非标定制外技术参数
执行标准:GB3836.1-2000,GB3836.2-2000,GB3836.3-2000,IEC60079
防爆标志:ExdⅡT6,*ExdⅡBT6,*ExedⅡCT6
额定电压:AC380/50Hz
额定电流:20A
防护等级:IP54,*IP55,*IP65
防腐等级:WF1
 BJX51-20/4防爆接线端子箱非标定制外产品特点
1、可用于380/220V及以下电路中作为连接各种电气设备的分线、接线用,也可作为自控或通讯的信号电源的
连线。
2、外壳采用高强度难燃工程塑料压制而成,外型美观且具有抗静电耐冲击及热稳定性好又耐腐蚀等优良性能。
3、盖与壳身之间设有密封圈,并用不锈钢螺钉紧固。
4、接线端子可采用压线式或菲尼克斯的增安型专用接线端子。
5、端子数出线口方向及数量,公称直径可任意变化。
6、符合GB3836-2000,IEC60079标准要求。
 BJX51-20/4防爆接线端子箱非标定制外适用范围
1.1区,2区危险气体场所;
 
2.ⅡA,ⅡB,ⅡC类T1-T5组爆炸性气体或蒸气环境;
3.户内,户外(IP54,IP65*订购时需提出)。