供应台湾表面温度计DE-306/DE-305
参考报价
¥0 / 套
起订量 0 套 · 价格可议 · 支持定制方案
供货能力30 套/月
发货地广东省 深圳市 宝安区
更新时间2019/11/11 18:54:30
已有 86 位采购商浏览
规格参数
品牌泰都
幸好td-690
产品介绍
台湾表面温度计DE-306/DE-305
产品说明
· 测量范围 : -50~1300 ℃ , -58 ℉ ~2372 ℉
· 分辨率 : 0.1 ℃ , 0.1 ℉
· 准确度 : -50 ℃ ~199.9 ℃ , 0.2% 读数 +1 ℃
·-58 ℉ ~391.8 ℉ , 0.2% 数数 +1 ℉
· 输入信号 : K
echnical
Temperature scale: ℃ or ℉ User-Selective.
Resolution: 1℃ or 1℉ (or 0.1℃ or 0.1℉)
User-Selective.
Inputs:Two K-type Thermocouples
Measurement Range:-50 ~ 1300℃(-59 ~ 2000℉)
Meter Operating Range:For Using at 0 ~ 50℃
Environment (32 ~ 122℉)
Accuracy:(18 ~ 28℃ ambient)
±(0.3% rdg + 1℃) –50 ~ 1000℃
±(0.5% rdg + 1℃) 1000 ~ 1300℃
±(0.3% rdg + 2℉) -58 ~ 2000℉
The accuracy specification does not include
type K thermocouple probe accuracy.
Temperature Coefficient:
0.1 times the applicable accuracy specification
per ℃ from 0℃ to 18℃ to 50℃.
Error Offset:Errors contributed by one particular thermocouple may be practically eliminated, over a limited measurement range, using a recessed front panel OFFSET adjust on the meter in an accurate temperature standard when making the adjustment. Although making the adjustment may increase measurement errors for using different thermocouples
Maximum Input: 60V dc or 24V rms ac
between the input pins or any input and ground.
General
Display :3 1/2 digit liquid crystal display (LCD)
with maximum reading of 1999.
Sampling Rate&nbs
产品说明
· 测量范围 : -50~1300 ℃ , -58 ℉ ~2372 ℉
· 分辨率 : 0.1 ℃ , 0.1 ℉
· 准确度 : -50 ℃ ~199.9 ℃ , 0.2% 读数 +1 ℃
·-58 ℉ ~391.8 ℉ , 0.2% 数数 +1 ℉
· 输入信号 : K
echnical
Temperature scale: ℃ or ℉ User-Selective.
Resolution: 1℃ or 1℉ (or 0.1℃ or 0.1℉)
User-Selective.
Inputs:Two K-type Thermocouples
Measurement Range:-50 ~ 1300℃(-59 ~ 2000℉)
Meter Operating Range:For Using at 0 ~ 50℃
Environment (32 ~ 122℉)
Accuracy:(18 ~ 28℃ ambient)
±(0.3% rdg + 1℃) –50 ~ 1000℃
±(0.5% rdg + 1℃) 1000 ~ 1300℃
±(0.3% rdg + 2℉) -58 ~ 2000℉
The accuracy specification does not include
type K thermocouple probe accuracy.
Temperature Coefficient:
0.1 times the applicable accuracy specification
per ℃ from 0℃ to 18℃ to 50℃.
Error Offset:Errors contributed by one particular thermocouple may be practically eliminated, over a limited measurement range, using a recessed front panel OFFSET adjust on the meter in an accurate temperature standard when making the adjustment. Although making the adjustment may increase measurement errors for using different thermocouples
Maximum Input: 60V dc or 24V rms ac
between the input pins or any input and ground.
General
Display :3 1/2 digit liquid crystal display (LCD)
with maximum reading of 1999.
Sampling Rate&nbs
联系我们
深圳市展华仪器仪表有限公司
- 联系人
- 邓二琳
- 联系电话
- 13613053014
- 公司地址
- 深圳市宝安区沙井中心路与北环路交汇处的卓越时代大厦407-3
- 主营产品
- 红外测温仪,红外热像仪,温度计,露点仪
- 服务时间
- 周一至周五 09:00-18:00
供应台湾表面温度计DE-306/DE-305
供应香港SMART短波红外测温仪AS882A/AS892
供应美国IRCON光纤式红外测温仪Modline6系列
供应涂层测厚仪MC-3000A/MC-3000C/MC-3000D
德国尼克斯涂层测厚仪QNix8500
供应香港SMART分体式照度计AS823/AS813一体式照度计
供应香港SMART工业型红外测温仪AS862A在线式红外测温仪AS882
供应德国菲希尔镀层厚度测量仪PMP10
供应德国Fischer两用涂层测厚仪MP0R/MP0